Huanyang inverter manual download

Chen yu chen bei industrial district, yuhuan town, taizhou city, zhejiang 317600 china subsidiary company. Huanyang vfd spindle calibration with mach3 within 1% duration. Measure and note the rpm of the motor shaft whilst the spindle is at 500rpm. Lapond svdes series vfd drive vfd inverter professional variable frequency drive 1. Never do wiring or other operations on the inverter with wet hands. Vfd inverter panel keypad keyboard control huanyang hy. Huanyang inverter vfd model number hy03d023binput 240 volt single phaserated output 220 volt 3 phase 4 hp or 3kw amps 220 volts x amps 2860 watts 1 hp 746 watts 4 x 746 watts 2984 watts initial setup. Recently i completed mechanical part and started final part, electrical.

Cant seam to work out which connection to use from the manual. It is not necessary to connect the spindle vfd variable frequency drive also called an inverter to the computer or cnc motion electronics. Please read carefully the operation manual before putting the inverter to use so as to correctly. Vfd manual huanyang drive free download as pdf file. Checks upon delivery the inverter has been strictly and well packed before exwork. Instruction manual high performance compact inverter thank you for purchasing our frenicmulti series of inverters. You will need to refer to the manual for an explanation of the various pds and the values that can be applied. Stumbling about with a copy of the manual in hand got it to work. I have a 4kw huanyang inverter on my lathe, i want to wire into it the foot stop, i have it mounted on my lathe so i can use the on off fwd rev and speed control all from the front of the inverter. The huanyang inverter is normally supplied with an instruction manual. In consideration of various factors during the transportation special attention should be paid to the following points before the assembly and installation. Connecting huanyang hy01d523b vfd speed controller to mach3 few months ago i purchased huanyang hy01d523b vfd and 1. Compare huanyang vfd price super offer from aliexpress. If there is any problem with the received product, please contact me and i will replace it for you see more product details.

If i setup 50hz for base frequency, spindle goes crazy and hot. Consult the huanyang instruction manual for details on using the face plate to program the vfds registers, and alternative values for the above registers. Change pd001 to 0 source of run commands change pd003 to 300 main frequency hz change pd004 to 300 base frequency hz change pd005 to 400 max operating frequency hz change pd006 to 2. This is setting according to the actual revolution of the motor this set value corresponds to the revolution at 50hz. There is also other information available from other sources, but none of them are very clear in explaining how to actually change the settings, so hopefully this page will. Be sure to turn off the input power supply before wiring. This product is designed to drive a threephase induction motor. How do i conect the vfd of the spindle to the rs485 connections current solution. After reading the manual, and altering all the parameters that were indicated, and rechecking the. Oct 01, 2016 chinese version is the standard one, english version is only for reference. Looking at the ebay ads it seems that the vdf unit is a huanyang hy02d223b. Hyria inverter series inverter manual hyria inverter hyria electrical co. This vfd keypad is suitable for huanyang hyseries 0. Cheap inverter 12v 220v w, buy quality vfd inverter directly from china inverter 5kw suppliers.

I understand that these ports allow for controlling the spindle speed, but im not sure how to properly connect them to the huanyang hy01d511b vfd and could use some direction on the proper wiring. About you plugin and my problem, please check page 54 of huanyang manual, specially about pd144 rated motor revolution. On the xcarve control board are two extra wiring ports. Change pd001 to 0 source of run commands change pd003 to 300 main frequency hz change pd004 to 300 base frequency hz change pd005 to 400 max operating frequency hz. Chinese version is the standard one, english version is only for reference. How do i conect the vfd of the spindle to the rs485. And the motor wire is connected with the terminals of u, v and w. Using serial comms control from mach3 by matty zee. Oct 31, 2018 huanyang vfd spindle calibration with mach3 within 1% duration. Even if you have computer control enabled, you can still stop the inverter by using the stop button. Huanyang 3kw vfd240 volt single phase to 220 volt 3 phase. Its provided purely as an example of what to add to it to get the huanyang vfd working, so dont use it on your machine verbatim.

Analog interface capabilityvariable speed potentiometer1 year. More to come, ill see if i can include seafurymikes excellent mach3 pwm manual. Huanyang hy series invertaer drives huanyang water cooled 400hz spindle. Product integration instructions connection c10c41 with huanyang january, 2015 set the jumper on the c41 for vfd huanyang. The instructions arent perfect kings english but they are easy to follow. Huanyang vfds canadian woodworking and home improvement forum. The motors on the machines have different settings for voltage and base frequency etc. I suggest you those electronic manuals for huanyang inverter in good quality note. How do i conect the vfd of the spindle to the rs485 connections. Fuji electric frenic mini series user manual pdf download.

It describes the various pd settings that can be applied. I think r and s are the 220 inputs and t is neutral possibly but i am not sure. Read through this instruction manual and be familiar with the handling procedure for correct use. Determine what kind of load machine is to be used, calculate its moment of inertia, and then select the appropriate motor capacity 2 key point. Is there a way you could explain this in a separate video or perhaps send me an instructions on programming. Read on for step by step config instructions and make reference to the config files in the download if need be. Huanyang vfds keep in mind in the two wire switching this is for a permanent contact only. Can you provide setting for the vfd setting for 110v us, 1.

Chen yu chen bei industrial district, yu huan town, taizhou city, zhejiang, china postal code. Download free software huanyang chinese vfd settings and. This is your responsibility, so do the right thing, be safe and. Product integration instructions connection c10c41 with. The following diagram is the standard wiring diagram for the vfdv inverter. In the three wire switching you can use pushbutton starts. Yes, i have set my minimum to 100hz and i can run it at 6000rpm water cooled spindle but id like to get more performance at intermediate speeds and i guess that it is uncorrect to leave pd006 2. How to program a vfd for a lathe tecowestinghouse l510 duration. Turn on the spindle using the manual mode on the vfd and adjust the speed control potentiometer until the spindle rpm as read on the tachometer is exactly 500rpm. If you look on page 3 of the manual, it says output voltage range. Much, much better than a typical huanyang instruction manual. For wiring of the inverter, it is divided into the main circuit and the control circuit. Lapond svdes series vfd drive vfd inverter professional.

Tai yau street san po kong, kowloon wong king industrial building 2. When the unit is powered up, after a delay of a few seconds, the power led glows, the numeric. Products including motor spindle, variable frequency drive, variable frequency drive. Read and understand the manuals safety instructions that should of came with your vfd inverter. Huanyang vfd inverter modbus base frequency was created by handy8000 i have one huanyang vfd and connect it to two machines not at the same time. Caution indicates wrong use may damage the inverter or mechanical system. Huanyang vfd inverter modbus base frequency linuxcnc. I think im supposed to use the 110v on the xcarve to the vfd, but i dont know.

Users could open the case cover, and could inspect the main circuit terminal and the control circuit terminal. Latest version of drufel cnc with a 100,000 lines of gcode. I think im supposed to use the 110v on the xcarve to the vfd, but i dont know where to connect the. Bill hardins lathe setup august 21, 2003 a lot of people have asked to see my 109. It still wants 5 seconds to warm up from off and start accelerating the motor parameters that i gave up trying to find but then i was impatient. The foot switch in open circuited until the foot brake is depressed. Huanyang inverter how to set and wire spindle at speed cnczone. Can anyone please tell me if it is possible to connect this vfd to my computer so that mach3 can control the spindle. Hy series inverter user manual edited by cncdiy cnc routing machine system 4 1. Im using a 5 hp huanyang inverter which is apparently only good for 3.